引用本文
  •    [点击复制]
  •    [点击复制]
PDF HTML全文阅读
本文已被:浏览 2542次   下载 1112 本文二维码信息
码上扫一扫!
超声内镜与CT诊断不同大小、性质胃黏膜下肿物的准确率比较
梁慧霞,胡颖华,戚美娅,闫再宏,王醒,董晓琳
河北中石油中心医院河北廊坊 065000
摘要:
目的:比较不同大小、性质胃黏膜下肿物的超声内镜(EUS)与CT诊断准确率。方法:选取2016年1月—2022年1月在我院治疗的胃黏膜下肿物患者80例,均给予EUS、CT检查,比较分析EUS、CT诊断结果。结果:经术后病理确诊60例为良性肿瘤,20例为恶性肿瘤。EUS诊断胃黏膜下肿物准确率为97.50%,明显高于CT诊断81.25%(P<0.05)。对于肿瘤直径<1 cm的胃黏膜下肿物,EUS诊断准确率为93.33%,明显高于CT诊断73.33%(P<0.05);对于肿瘤直径1~2 cm、>2 cm胃黏膜下肿物,EUS和CT诊断准确率比较差异无统计学意义(P>0.05)。EUS诊断良性胃黏膜下肿物的准确率为96.67%,明显高于CT诊断83.33%(P<0.05);EUS和CT诊断恶性胃黏膜下肿物准确率差异无统计学意义(P>0.05)。恶性间质瘤回声均匀、边界清楚比例分别为30.00%和35.00%,明显低于良性胃间质瘤79.55%、81.82%(P<0.05),恶性胃间质瘤形态不规则、不均匀强化、有坏死、局部侵犯比例分别为65.00%、70.00%、60.00%和65.00%,明显高于良性胃间质瘤(P<0.05)。结论:与CT检查相比,EUS诊断胃黏膜下肿物有较好的应用价值,尤其对于肿瘤直径<1 cm的肿物或良性肿瘤,其诊断价值较高。
关键词:  胃黏膜下肿物  超声内镜  计算机断层扫描术  诊断准确率中图分类号:R735.2 文献标识码:A 文章编号:1007-6948(2023)01-0092-07
DOI:10.3969/j.issn.1007-6948.2023.01.019
基金项目:河北省廊坊市科学技术研究与发展计划(2020013128)
Comparison of EUS and CT diagnostic accuracy of gastric submucosal masses with different sizes and properties
LIANG Hui-xia,HU Ying-hua,QI Mei-ya
Department of Gastroenterology, Hebei CNPC Central Hospital, Langfang, Hebei 065000, China
Abstract:
Objective To compare the diagnostic accuracy of endoscopic ultrasonography (EUS) and CT for gastric submucosal tumors of different sizes and properties. Methods 80 patients with gastric submucosal masses treated in our hospital from January 2016 to January 2022 were examined by EUS and CT, and the diagnostic results of EUS and CT were compared and analyzed. Results Postoperative pathology confirmed that 60 cases were benign tumors and 20 cases were malignant tumors, the accuracy of EUS in diagnosing gastric submucosal masses was 97.50%, which was significantly higher than that of CT81.25% (P<0.05). For gastric submucosal masses with tumor diameter < 1 cm, the diagnostic accuracy of EUS was 93.33%, which was significantly higher than that of CT73.33% (P<0.05). There was no significant difference in diagnostic accuracy between EUS and CT for gastric submucosal masses with tumor diameter of 1~2 cm and tumor diameter > 2 cm (P>0.05). Gastric submucosal mass with tumor diameter < 1 cm, the accuracy of EUS was 96.67%, which was significantly higher than that of CT83.33% (P<0.05).There was no significant difference in the accuracy of EUS and CT in diagnosing malignant gastric submucosal masses (P>0.05). The proportion of uniform echo and clear boundary in malignant stromal tumor was 30.00% and 35.00%, which was significantly lower than that in benign gastric stromal tumor 79.55%、81.82% (P<0.05), The proportions of malignant gastric stromal tumors with irregular shape, uneven enhancement, necrosis and local invasion were 65.00%, 70.00%, 60.00% and 65.00% respectively, which were significantly higher than those of benign gastric stromal tumors (P<0.05). Conclusion Compare with CT examination, EUS has better application value in the diagnosis of gastric submucosal tumors, especially in tumor
Key words:  Submucosal tumor of stomach  endoscopic ultrasonography  CT  diagnostic accuracy reperfusion  lung injury  NLRP3 in.ammasome  in.ammatory cytokines

用微信扫一扫

用微信扫一扫